Reports until 09:59, Monday 21 July 2014
H1 PSL
patrick.thomas@LIGO.ORG - posted 09:59, Monday 21 July 2014 (12889)
PSL check
LASER is on
Frontend output power is 36.2 W, HPO output power is 29.9 W
Watchdog is green
'LRA out of range' error is active [OUT OF SPEC]

PMC:
Locked for 1 day 19 hours
Reflected power is 19.5% of transmitted power (should be 10% or less) [OUT OF SPEC]

FSS:
Locked for 1 day 19 hours
Trans PD threshold is .4 V, should be at least .9 V [OUT OF SPEC]

ISS:
Diffracted power is ~ 9% (should be ~10%)
Last saturation event was 1 day 19 hours ago