Reports until 16:32, Friday 25 July 2014
H1 SUS
stuart.aston@LIGO.ORG - posted 16:32, Friday 25 July 2014 - last comment - 16:40, Friday 25 July 2014(13001)
Matlab TFs running on MC1 and MC3 (HSTS) overnight
Matlab TFs are set to run on HAM2 suspensions overnight as follows:-  

- MC1 (HSTS) M1-M1 undamped TFs
- MC1 (HSTS) M2-M2 undamped TFs
- MC1 (HSTS) M3-M3 undamped TFs

- MC3 (HSTS) M1-M1 undamped TFs
- MC3 (HSTS) M2-M2 undamped TFs
- MC3 (HSTS) M3-M3 undamped TFs

Starting now, and when complete the measurement status will revert to OFF and damping loops will be restored to the ON state.

n.b. all stages of the above suspensions have been configured to Coil Driver BIO state 1 to try and limit any DAC saturations.

These measurements have been initiated from the opsws2 workstation.
Comments related to this report
arnaud.pele@LIGO.ORG - 16:40, Friday 25 July 2014 (13002)

PRM PR3 (all stages) and MC2 PR2 (M2 M3) started around 4:40 on opsws1. HAM2 ISI is Isolated HAM3 ISI is Damped.