Displaying report 1-1 of 1.
Reports until 10:42, Thursday 31 July 2014
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 10:42, Thursday 31 July 2014 - last comment - 10:47, Thursday 31 July 2014(13109)
Port scan on H1FE network appears to have crashed h1broadcast0 daqd process

After first verifying that no critical measurements were being taken, I performed an nmap port scan of the H1FE VLAN. This caused the daqd process on h1broadcaster to fail, it was subsequently restarted by monit.

I ran the port scan a second time, and h1broadcast0 daqd did not fail this time.

The log files show a correlation between port scan and the failure. I will exclude all DAQ hosts from future port scans.

Comments related to this report
david.barker@LIGO.ORG - 10:47, Thursday 31 July 2014 (13111)

log file for this event attached.

Non-image files attached to this comment
Displaying report 1-1 of 1.