As per ECR E1400262, and work permit 4764, I've created a new set of channels for the to-be-installed UWash Beam Rotation Sensor (BRS) in the top level of h1isietmx front-end model. This required re-compiling, re-installing, restarting, and restoring the h1isietmx front end process, and a restart of the data concentrator / frame builder / h1dc0 (restarted at 22:48 UTC). Again, because this is all at the top level, not library parts are affected, and I've committed the updated model to the userapps repo.

I've also added two new channels to the frames, 
H1:ISI-GND_BRS_ETMX_RY_IN1_DQ 
H1:ISI-GND_BRS_ETMX_RY_OUT_DQ
both stored at 256 [Hz], and only the OUT channel (which will be the calibrated channel) in the science frames. More details on the calibration once we get the sensor installed. MEDM screen also to come.

I was able to restore the platform to fully isolated, managed by guardian, before handing over to Jim for over-night measurements.