Reports until 08:49, Saturday 09 August 2014
H1 DAQ (CDS)
david.barker@LIGO.ORG - posted 08:49, Saturday 09 August 2014 - last comment - 12:49, Saturday 09 August 2014(13310)
DAQ problems

Two unrelated problems with the DAQ ongoing:

1. disk9 of the DCS raid system for h1fw0 failed at 10pm Friday night. h1fw0 lost its file system at 1:50am this morning and has not been running since then.

2. h1susim front end has failed and has caused a DAQ error for the following frontends: h1susb123, h1sush2a, h1sush34, h1sush56, h1susauxh2, h1susauxh34, h1susauxh56, h1sieb1, h1sieb2, h1seib3, h1seih16, h1seih23, h1seih45, h1psl.

both end stations have good DAQ data.

I've emailed LDAS regarding the disk failure in the LDAS server room.

For problem 2, I'm going to try restarting the DAQ data stream from those frontends.

Comments related to this report
david.barker@LIGO.ORG - 09:07, Saturday 09 August 2014 (13311)

tried restarting MX streams on h1susb123, but no dice. I suspect the fact that h1sush2b has completely failed is actively causing the problem.

Looking at the hourly burts, h1susim front end failed between 11pm  and midnight Friday night. The related DAQ errors happened at the same time.

david.barker@LIGO.ORG - 12:49, Saturday 09 August 2014 (13312)

here is the cds overview during this DAQ problem

Images attached to this comment