I have compiled all models using RCG2.8.5 in preparation for Thursday's upgrade. The procedure was:
-
Save the H1.ipc file
-
create a new H1.ipc file by running "make -i World" (skip errors, force IPC writers into ipc file)
-
run "make World", failed at h1susauxb123 due to SPSZ part. Jeff and Arnaud instructed me to remove this part from the model, which I did and committd to svn
-
run "make World" a second time, failed at h1susquadtst. This is an out of date top level model not synced with QUAD_MASTER. Took this out of rtsystab for now
-
run "make World" a third time, all compiled.
-
Saved the "2.8.5" version of H1.ipc and restored this file to this morning's version.
If anyone needs to compiled models today or tomorrow, please email me as I may have to rebuild against the new IPC file tomorrow.