kyle.ryan@LIGO.ORG - posted 17:48, Tuesday 12 August 2014 (13370)
Helium sprayed YBM and Vertex
Gerardo, Kyle 

Following John and Bubba's final-torquing of the under-torqued viewport on HAM4 (S. door, bottom middle) and also HAM5 S. door bottom left -> Kyle and Gerardo sprayed audible bursts of helium (up to 3 feet away or closer) at viewports, feedthroughs and all accessible flanges -> Helium baseline drifted slowly up from 9x10-9 mbar*L/sec to 3x10-8 mbar*L/sec during the test period (lots of helium sprayed)

This was not an exhausted test, some flanges were not accessible (light pipes sealed off with aluminized tape etc)., in most cases, flange leak test ports were not pressurized - though big leaks should have responded.  