ETMY and ETMX ESD
Added the ESD Bias Path Filter Box (D1400192) to both ETMY and ETMX.
Units filter voltage noise present on the ETM bias path of the ESD HV drive.

Due to wiring differences inside the chamber, the filter units were connected as follows:
ETMY connected to pin 1 (Flange F2-3)
ETMX connected to pin 3 (Flange F2-3)

Filiberto Clara
Comments related to this report
filiberto.clara@LIGO.ORG - 14:26, Wednesday 13 August 2014 (13393)
EX
Current Limit Box D1201288      SN S1400223
ESD Bias Path Filter D1400192 SN S1400403

EY
Current Limit Box D1201288      SN S1400224
ESD Bias Path Filter D1400192 SN S1400405