Late entry for Wednesday's restarts
model restarts logged for Wed 13/Aug/2014
2014_08_13 00:39 h1fw1
2014_08_13 01:39 h1fw1
2014_08_13 09:29 h1fw1
2014_08_13 10:48 h1nds1
2014_08_13 10:57 h1nds1
2014_08_13 13:15 h1iopoaf0
2014_08_13 13:15 h1oaf
2014_08_13 13:15 h1odcmaster
2014_08_13 13:15 h1pemcs
2014_08_13 13:15 h1tcscs
2014_08_13 13:24 h1iopoaf0
2014_08_13 13:24 h1oaf
2014_08_13 13:24 h1odcmaster
2014_08_13 13:24 h1pemcs
2014_08_13 13:24 h1tcscs
2014_08_13 18:31 h1ioppsl0
2014_08_13 18:31 h1pslfss
2014_08_13 18:31 h1pslpmc
2014_08_13 18:33 h1psldbb
unexpected restarts of h1fw1. Some DAQ min trend work required nds restarts. Stuck PEM ADC channels required h1oaf0 restarts (residual from Tue power glitch). PSL restart part of power outage shutdown prep.