jeffrey.kissel@LIGO.ORG - posted 16:38, Friday 22 August 2014 (13567)
H1 SUS OMCS OK for Doors Closed
J. Kissel

Completed a set of Phase 3a transfer functions and spectra to confirm the health of the OMCS before we close doors on Monday. Results look good, and comparable to previous measurements and LLO's OMC, sensors show noise comparable to what is expected. This SUS is clear for chamber close up.

TF DTT Templates:
/ligo/svncommon/SusSVN/sus/trunk/OMCS/H1/OMC/SAGM1/Data/
2014-08-22_1739_H1SUSOMC_WhiteNoise_L.xml
2014-08-22_1739_H1SUSOMC_WhiteNoise_P.xml
2014-08-22_1739_H1SUSOMC_WhiteNoise_R.xml
2014-08-22_1739_H1SUSOMC_WhiteNoise_T.xml
2014-08-22_1739_H1SUSOMC_WhiteNoise_V.xml
2014-08-22_1739_H1SUSOMC_WhiteNoise_Y.xml

TFs processed by 
/ligo/svncommon/SusSVN/sus/trunk/OMCS/Common/MatlabTools/plotOMCS_dtttfs.m

TFs .mat file 
/ligo/svncommon/SusSVN/sus/trunk/OMCS/H1/OMC/SAGM1/Results/2014-08-22_1739_H1SUSOMC_M1.mat

TFs compared with other previous results using
/ligo/svncommon/SusSVN/sus/trunk/OMCS/Common/MatlabTools/plotallomcs_tfs.m

Spectra taken by
/ligo/svncommon/SusSVN/sus/trunk/OMCS/Common/MatlabTools/plotomcs_spectra.m

ASD saved to
/ligo/svncommon/SusSVN/sus/trunk/OMCS/Common/Data/2014-08-22_1739_H1SUSOMC_M1_Spectra.mat

Spectra compared against others using
/ligo/svncommon/SusSVN/sus/trunk/OMCS/Common/MatlabTools/plotallomcs_spectra.m

All data and scripts committed to to SusSVN.