Nicolas, Keita, Dave
The h1omc model was modied. In the ASC block, 8 filtermodules were removed and 4 were added downstream. In the DAQ list, 8 OUT channels were removed and 4 OUT were added (all at 2048Hz). Four CLOCK channels were connected to the CLK outputs of the oscillators (previously they were tee'ed to the SIN outputs).
After the model was restarted, we restarted the DAQ to sync with the new INI file. The safe.snap restore was not good, so I manually burt restored to 16:10 (h1omc safe.snap needs updating).
Attached is an illustrated summary of the filter bank changes.