daniel.sigg@LIGO.ORG - posted 16:26, Tuesday 02 September 2014 (13713)
Baffle PD controller in EX
The X-end controller for the baffle diodes was still one of the early units with parts missing (BO at the time). Swapped S1302233 with S1400075; and updated the Beckhoff to reflect these changes. It is now possible to adjust the gains remotely.