(Corey, Greg, Jim)
Unit#2 CPS Swap
Have swapped out the Capacitive Position Sensors (CPS) on Unit#2; originally-installed ones had bad flux/solder. All of the new CPS's were installed with the ISI Locked and we were able to get voltages (read off Voltmeter) under 0.2V [most were close to ~0V]; note: these voltages were observed to change when one touched various Stages and when the System was Unlocked.
When installing these Sensors, we observed that 1 of the 12 had issues (the voltage remained max-ed at ~13V no matter where the Target was located); this is a Fine-range Sensor. This one was swapped out for a spare & it was installed and operational.
After the CPS's were installed the system was Unlocked. Vincent will now check on the functionality of these Sensors.
Here is information for the CPS Probes & Boards/Gauges:
|
Location |
Gauge type |
Gauge S/N |
Probe type |
Probe S/N |
Master/Slave |
Phase |
Sensitivity |
|
ST1 - H1 |
8800 |
15881 |
2822-V |
13576 |
Master |
0 |
Coarse |
|
ST1 - H2 |
8800 |
15854 |
2822-V |
13583 |
Slave |
180 |
Coarse |
|
ST1 - H3 |
8800 |
13066 |
2822-V |
13180 |
Slave |
0 |
Coarse |
|
ST1 - V1 |
8800 |
12831 |
2822-V |
13572 |
Slave |
180 |
Coarse |
|
ST1 - V2 |
8800 |
13062 |
2822-V |
13620 |
Slave |
0 |
Coarse |
|
ST1 - V3 |
8800 |
15860 |
2822-V |
13577 |
Slave |
180 |
Coarse |
|
ST2 - H1 |
8800 |
15874 |
2822-V |
13415 |
Slave |
0 |
Fine |
|
ST2 - H2 |
8800 |
15864 |
2822-V |
13575 |
Slave |
180 |
Fine |
|
ST2 - H3 |
8800 |
12427 |
2822-V |
12901 |
Slave |
0 |
Fine |
|
ST2 - V1 |
8800 |
15865 |
2822-V |
13573 |
Slave |
180 |
Fine |
|
ST2 - V2 |
8800 |
15867 |
2822-V |
13465 |
Slave |
0 |
Fine |
|
ST2 - V3 |
8800 |
15863 |
2822-V |
13578 |
Slave |
180 |
Fine |
Unit#2 Cables Inventory:
Here are the drawing numbers used for Unit2 in-vacuum cables (except for the CPSs):
Corner1
Actuators
GS13: D1000221 -100
L4C: D1000221 -100
Trillium: D1000221 -100
Corner2
Actuators
GS13: D1000221 -100
L4C: D1000221 -100
Trillium: D1000221 -100
Corner3
Actuators
GS13: D1000221 -100
L4C: D1000221 -100
Trillium: D1000221 -100