Displaying report 1-1 of 1.
Reports until 19:02, Tuesday 02 September 2014
H1 ISC
sheila.dwyer@LIGO.ORG - posted 19:02, Tuesday 02 September 2014 (13722)
End X ready for a peak down the arm

Lisa, Sheila

We went down to end X, turned on the laser, adjusted the fiber polarization, adjusted the laser temperature to find the beat note, tuned up the beat note alignment, and the PLL is now locked.  The QPD servos are also locked.

There is 6.5 mW on the PLL BBPD, the medm screen reports -5.6 dBm beat note strength, and the laser temperature is 28.96 C. 