Displaying report 1-1 of 1.
Reports until 17:27, Friday 09 September 2011
H2 General
christopher.guido@LIGO.ORG - posted 17:27, Friday 09 September 2011 - last comment - 17:46, Friday 09 September 2011(1374)
S1103182 Chasis changes (again) and recalibration
Steve O'Connor, Aidan Brooks, Christopher Guido

Wednesday night, we made a series of resistor changes to the S1103182 chassis(on both boards S1103183 and S1103184)which can be seen in yesterday's post, but today, we reverted the resistors back to the original values except for R44. These changes will be uploaded to the traveler. 

Afterwards, we tested the board (results attached as excel spreadsheet) and used the results to calibrate the H2TCS-ITMY_RING_HEATER screen. The changes to the gain and offset(in the filters) are listed below

H2TCS_ITMY_RING_HTR_SEG1_I_MON 
Offset = -3.22 counts
Gain   = -0.0247 mA/count

H2TCS_ITMY_RING_HTR_SEG2_I_MON
Offset = -7.135 counts
Gain   = -2.456e-2 mA/count 

H2TCS_ITMY_RING_HTR_SEG1_V_MON 
Offset = -145.2 counts
Gain   = 1.281e-3 V/count

H2TCS_ITMY_RING_HTR_SEG2_V_MON 
Offset = -129.9 counts
Gain   = 1.364e-3 V/count
Non-image files attached to this report
Comments related to this report
aidan.brooks@LIGO.ORG - 17:46, Friday 09 September 2011 (1375)
Full details of ring heater calibrations. We noted that the measured current to the load was about 3.5% lower than the requested current. Once the ring heater is actually in place we plan on doing a more thorough calibration.

H2:TCS-ITMY_RING_HTR_SEG1_I_MON_OFFSET = -3.22 counts
deWhiten = zero at 0.4Hz, poles at 10 Hz, 1000Hz
H2:TCS-ITMY_RING_HTR_SEG1_I_MON_GAIN = -2.47E-2 mA/count

H2:TCS-ITMY_RING_HTR_SEG1_V_MON_OFFSET = -145.2 counts
deWhiten = zero at 0.4Hz, poles at 10 Hz, 1000Hz
H2:TCS-ITMY_RING_HTR_SEG1_I_MON_GAIN = 1.283E-3 V/count

H2:TCS-ITMY_RING_HTR_SEG1_TEMPERATURE_MON_OFFSET = -16192 counts
pole0.3Hz = pole at 0.3Hz
H2:TCS-ITMY_RING_HTR_SEG1_TEMPERATURE_MON_GAIN = 1.6E-2 deg C/count

H2:TCS-ITMY_RING_HTR_SEG1_LV_MON_GAIN = 1.235E-3 V/count

H2:TCS-ITMY_RING_HTR_SEG1_AC_I_SET_GAIN = 40.96 counts/mA
H2:TCS-ITMY_RING_HTR_SEG1_DC_I_SET_GAIN = 40.96 counts/mA

H2:TCS-ITMY_RING_HTR_SEG1_ISQR_PWR_RAD_GAIN = 1E-6 W^2/(mW^2)
H2:TCS-ITMY_RING_HTR_SEG1_MEASURED_R_GAIN = 1E3 Ohms/(kOhm)
H2:TCS-ITMY_RING_HTR_SEG1_VI_PWR_RAD_GAIN = 1E-3 W/(mW)

H2:TCS-ITMY_RING_HTR_SEG2_I_MON_OFFSET = -7.1 counts
deWhiten = zero at 0.4Hz, poles at 10 Hz, 1000Hz
H2:TCS-ITMY_RING_HTR_SEG2_I_MON_GAIN = -2.456E-2 mA/count

H2:TCS-ITMY_RING_HTR_SEG2_V_MON_OFFSET = -129.9 counts
deWhiten = zero at 0.4Hz, poles at 10 Hz, 1000Hz
H2:TCS-ITMY_RING_HTR_SEG2_I_MON_GAIN = 1.364E-3 V/count

H2:TCS-ITMY_RING_HTR_SEG2_TEMPERATURE_MON_OFFSET = -16192 counts
pole0.3Hz = pole at 0.3Hz
H2:TCS-ITMY_RING_HTR_SEG2_TEMPERATURE_MON_GAIN = 1.6E-2 deg C/count

H2:TCS-ITMY_RING_HTR_SEG2_LV_MON_GAIN = 1.235E-3 V/count

H2:TCS-ITMY_RING_HTR_SEG2_AC_I_SET_GAIN = 40.96 counts/mA
H2:TCS-ITMY_RING_HTR_SEG2_DC_I_SET_GAIN = 40.96 counts/mA

H2:TCS-ITMY_RING_HTR_SEG2_ISQR_PWR_RAD_GAIN = 1E-6 W^2/(mW^2)
H2:TCS-ITMY_RING_HTR_SEG2_MEASURED_R_GAIN = 1E3 Ohms/(kOhm)
H2:TCS-ITMY_RING_HTR_SEG2_VI_PWR_RAD_GAIN = 1E-3 W/(mW)
Displaying report 1-1 of 1.