Reports until 08:27, Thursday 04 September 2014
H1 PSL (PSL)
peter.king@LIGO.ORG - posted 08:27, Thursday 04 September 2014 (13750)
PSL Relative Power Noise
Now that the ISS is back working after re-aligning into the pre-modecleaner, it makes sense to do a measurement.

The measurement looks better than the one performed on August 12th in that the hump out beyond 1 kHz is cleaner now than before.  The low frequency relative power noise appears to be a little better from 1-3 Hz.  One difference to note is that the diffracted light level is ~2% higher than before.  Also the first loop gain is lower at 8 dB versus 17 dB (old).  With the improved alignment, the power on the photodetector is ~10V versus ~8.6V.