Installed new OMC alignment matrices

The matrices described in 13703 were installed. This caused a noticable improvement in the shape of the QPD alignment OLGs. They are now more clearly a clean 1/f shape.

I also tuned the OMC LSC demod phase and set the gain for a 80Hz UGF. (This was done by opening the LSC loop and sitting on the side of a resonance and tuning the phase until the Q signal was 0)

Images attached to this report
Comments related to this report
koji.arai@LIGO.ORG - 17:44, Saturday 06 September 2014 (13800)

I suppose the matrices Nic used are the ones described in T1400585