Reports until 15:01, Tuesday 09 September 2014
H1 SEI (AOS)
jeffrey.kissel@LIGO.ORG - posted 15:01, Tuesday 09 September 2014 (13838)
HAM4 & HAM5 Table Optical Levers added to ISI Front-End Models and sitemap
J. Kissel, D. Barker

Completing the work I'd started with the HAM4 & 5 table optical levers (see LHO aLOG 13785), I recompiled, reinstalled, restarted and restored (4R'd) the HAM4 and 5 user models (h1isiham4, h1isiham5) to install the table oplev infrastructure. 

Note to the seismic team: we should modify the generic HAM-ISI overview screen to include a link to their respective oplev screen, instead of having these be separate line items in the sitemap pull down menu. Even better -- if anyone ever intends to *use* these levers -- we should make the infrastructure like the rest of the QPD / Optical lever world, and use the QPD Simulink library part, as well as the same screen. 

*ahem*...

Detailed list of activities
- Ramping down each ISI to the "READY" state, turning off the master switch
- Capturing  a new safe.snap for each (and committing the result to the userapps svn repo)
- Recompiling, reinstalling, restarting, and restoring the HAM4 and HAM5 models
- Restarting the DAQ / frame builder / data concentrator -- this failed, because of a duplicate channel naming bug in the HAM4 model 
- Fixing the bug in the HAM4 model
- Recompiling, reinstalling, restarting, and restoring the HAM4 model
- Restarting the DAQ / frame builder / data concentrator
- Turning on the HAM4 & HAM5 master switch, and returning HAM4 to "HIGH ISOLATED" and HAM5 to "ROBUST ISOLATED" via guardian.
- Committing the updated models to the userapps svn repo
- Adding the HAM4 and HAM% optical lever screens to the corner station ISI pulldown menu on the sitemap
- Committing the new sitemap to the userapps svn repo.