I readjusted the demodulation phase of all the REFL WFSs. This time, instead of using a IMC excitation techqnue, I simply used a free swinging PRX signal and minimized the q-signals. The phases were adjusted such that every segment has the same sign.
In the process, I found that five RF cables disconnected from the field rack. Bad. This explains why we did not have a good signal in REFL_A_RF9_SEG4. I plugged them back in. Now they can see reasonable signals.
=======
H1:ASC-REFL_A_RF9_SEG1_PHASE_R -75.5
H1:ASC-REFL_A_RF9_SEG2_PHASE_R -55
H1:ASC-REFL_A_RF9_SEG3_PHASE_R -58
H1:ASC-REFL_A_RF9_SEG4_PHASE_R -75
H1:ASC-REFL_B_RF9_SEG1_PHASE_R -83
H1:ASC-REFL_B_RF9_SEG2_PHASE_R -85
H1:ASC-REFL_B_RF9_SEG3_PHASE_R -85
H1:ASC-REFL_B_RF9_SEG4_PHASE_R -79
H1:ASC-REFL_A_RF45_SEG1_PHASE_R -116
H1:ASC-REFL_A_RF45_SEG2_PHASE_R -90
H1:ASC-REFL_A_RF45_SEG3_PHASE_R -86.4
H1:ASC-REFL_A_RF45_SEG4_PHASE_R -104.3
H1:ASC-REFL_B_RF45_SEG1_PHASE_R -178
H1:ASC-REFL_B_RF45_SEG2_PHASE_R -179
H1:ASC-REFL_B_RF45_SEG3_PHASE_R 178