A. Sevingy, J. Kissel, A. Staley Continuing with the installation of modified triple acquisition drivers into all lower stages of Recycling Cavity HSTSs, as per ECR E1400369, Integration Issue 936, and work permit 4850. Aaron will post serial numbers when the final install of SRM is complete, however, anxious to use the new drivers, Alexa and I followed yesterday's procedure (see LHO aLOG 13958, we started at Step 2) to make the necessary software changes to support the new drivers on H1SUSPR2 and H1SUSSR2. The only difference was that, unlike PRM, the "twos" needed BOTH stages of COILOUTF filters modified, since they did not have a prior modified driver installed in M2. new safe.snaps, filter files, and top-level models have been committed to the userapps repo. As with yesterday's changes, no DAQ restart was required.
Same has been done for SRM now.