SRM and PRM crossovers checked

Last night we roughly adjusted the cross overs of SRM and PRM to be about 4.5 Hz, I have checked both cross overs using PRX and SRY.  I adjusted the gain in FM1 of M2 lock for both suspensions, so it is still true that the gain you enter for M2 will be the cross over frequency.