Reports until 10:28, Monday 22 September 2014
H1 General
andres.ramirez@LIGO.ORG - posted 10:28, Monday 22 September 2014 (14063)
PSL Weekly Check
PSL Check: 9/22/2014

Laser Status: 
SysStat: Warning “VP program online” is red
Output power is 29.6 W (should be around 30 W)
FRONTEND WATCH is active
HPO WATCH is red

PMC:
It has been locked 5 days,0 hr , and 59 minutes (should be days/weeks)
Reflected power is 2.2 Watts and PowerSum = 25.9 Watts.
(Reflected Power should be <= 10% of PowerSum)

FSS:
It has been locked for 3 d, 20 h, and 38 min (should be days/weeks)
Threshold on transmitted photo-detector PD = 2.03 V (should be at least 0.9V)

ISS:
The diffracted power is around 7.1 % (should be 5-15%) 

Last saturation event was 4 d, 22 h and 51 minutes ago (should be days/weeks)