B. Weaver, T. Sadecki, D. Sellers
Today we laced reaction chain cables and plugged in UIM and PenRe OSEMs. We then began another round of R0 TFs. TF results pending. Offsets and gains for the lower stages are as follows:
L1UL 19173 1.565 -9586
L1LL 27412 1.094 -13706
L1UR 24370 1.231 -12185
L1LR 23612 1.271 -11806
L2UL 22949 1.307 -11474
L2LL 24546 1.222 -12273
L2UR 24855 1.207 -12428
L2LR 23608 1.271 -11804
These have been loaded to MEDM.
We noted that the Q6 UIM L1 UL BOSEM was very low voltage. Today, Travis and Danny switched in a new one. We've updated the open light voltage offset and gain and loaded to MEDM.
After this change, now with serial numbers: