Reports until 11:04, Thursday 25 September 2014
H1 SUS
keita.kawabe@LIGO.ORG - posted 11:04, Thursday 25 September 2014 - last comment - 14:14, Thursday 25 September 2014(14144)
OL sign convention

Daniel and I have found that the optical lever sign convention for ETMs and ITMs was changed in May/2013, and now it's opposite of what I remember.

I'd like to know why it is/was a good idea.

Right now, the dot on the screen goes up when the OL beam goes down.

Comments related to this report
thomas.vo@LIGO.ORG - 14:14, Thursday 25 September 2014 (14149)

It probably was changed so that the convention matches the SUS coordinate system so that positive pitch in the OSEMS should read positive pitch in the OLs, if this isn't the case then it's an error.