EY green WFS DC centering (Keita, Daniel)

These are working again. We needed to align things on the table, as it was previously done with some random alignment.

The filter gains are +500000 counts for WFSA PIT/YAW and WFSB PIT, but -500000counts for WFSB YAW.

UGF is 10-12Hz for WFSA and 8Hz-ish for WFSB with these gains.

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 14:59, Friday 26 September 2014 (14178)

EPICS settings of the auto-centering servos.

Eight minute trend of the control outputs.
We are using a significant amount of the available range (±16000).

Eight second dataviewer plot of outputs (WFS_A PIT is bipolar, all other unipolar).

Images attached to this comment