Displaying report
1
-
1
of
1
.
Reports until 05:51, Saturday 27 September 2014
H1 ISC
Link
kiwamu.izumi@LIGO.ORG -
posted 05:51, Saturday 27 September 2014
(14188)
IM4/PR2 ASC loop tuned up, POP_RF18_I is higher
I tuned up the input pointing ASC loop which I closed yesterday (
alog 14162
).
see the attached for the loop parameters.
Locked PRMI and found POPAIR_RF18 at a high value of 200 uW.
One difference from the past is that IM4 had been servoed to a small bias in pitch (~11000 urad) by the IM4/PR2 loop.
Images attached to this report
Displaying report
1
-
1
of
1
.