WP 4869 The user environment has been changed to set up the awgstream environment properly. The CERN ROOT package has been replaced with a version that supports python. The gds software (diaggui, foton, etc) has been updated to gds-2.16.12.2, which has a number of bug fixes and a few enhancements: * python scripting capability for awg and foton have been added. * Cut/paste added to the Calibration dialog box in diaggui (and foton). * Long channel names are no longer ignored in the Calibration dialog box. * Fix bug preventing diaggui from reliably making continuous measurements. * Unsigned 32 bit integer data support for diaggui time series. * Foton legacy write option has been removed. * Fix foton bugs for file path option, add "-o" option for non-gui file processing. * Fix foton bug which caused crashes when invoked from diaggui.