J. Kissel
After updating the IOP software watchdog (SWWD) status channel to obey the
${IFO}:IOP-SUS_${OPTIC}_DACKKILL_STATE
convention back in June 2014 (see LHO aLOG 12504), Arnaud had updated the SUS overview screens to match, (see LHO aLOG 12550), but we never committed them, because LLO and LHO were pioneering and prototyping ESD linearization (see 11874), and LLO did not plan to upgrade their RCG and IOP watchdogs for quite some time.
The two sites models and MEDM screens (especially the QUADs) have diverged so much now that its become intractable to maintain. As such, we're beginning the process of reconciling the models by committing these IOP SWWD changes.
svn commit -m "Updated IOP SWWD channel name. See LHO aLOG 12550." bsfm/SUS_CUST_BSFM_OVERVIEW.adl quad/SUS_CUST_QUAD_R0.adl quad/SUS_CUST_QUAD_OVERVIEW.adl omcs/SUS_CUST_OMCS_OVERVIEW.adl hxts/SUS_CUST_HLTS_OVERVIEW.adl hxts/SUS_CUST_HSTS_OVERVIEW.adl tmts/SUS_CUST_TMTS_OVERVIEW.adl SUS_CUST_IOP_DACKILL.adl
Sending SUS_CUST_IOP_DACKILL.adl
Sending bsfm/SUS_CUST_BSFM_OVERVIEW.adl
Sending hxts/SUS_CUST_HLTS_OVERVIEW.adl
Sending hxts/SUS_CUST_HSTS_OVERVIEW.adl
Sending omcs/SUS_CUST_OMCS_OVERVIEW.adl
Sending quad/SUS_CUST_QUAD_OVERVIEW.adl
Sending quad/SUS_CUST_QUAD_R0.adl
Sending tmts/SUS_CUST_TMTS_OVERVIEW.adl
Transmitting file data ........
Committed revision 8750.
Stuart will now begin the arduous process of upgrading the SUS top-level, library, and IOP models to RCG 2.9. Then, he can push forward with bringing the library parts up-to-date with LLO's detached models, such that LHO can inherit all the good development work they've been doing down south. All yours Stuart!