EY WFS

(Keita Daniel)

We are setting up the feedback paths for the EY WFS servos. Simple 1/s filters are currently loaded into DOF_3 and DOF_4.

We noticed that the IPCs for feeding back to the test masses were set up in the ISCEY model, but that they were only connected for EX in the ASC model. The ASC model was changed on disk but no yet committed.

The cameras with the green filters blocking the 1064nm wavelength are working on the ITMs. Exposure set to 30,000. The images look rather different between X and Y, so.

Added additional offsets and normalization capabilities to the camera position code in the ISC end station models. Needs to be loaded. A new medm screen was also added.