In the interest of time, using good 'ol foton, I've installed the basic electronics compensation and damping filters that we've been using thus far to commission the BSFM/QUAD in the assembly area, since it's basically the same electronics. These include (notation is [zeros:poles], every filter has a gain of 1). - In the M1 OSEMINF banks, compensation for the analog whitening in the Satellite Amplifiers, a [10:0.4] dewhitening filter. - In the M1 COILOUTF banks, compensation for the analog dewhitening of the "acquire" state of the TOP coil driver. a [1:31] anti-dewhitening filter (note, as with the QUAD, there is an additional state [1,1:10,31], but I have not yet installed that filter) - In the M1 DAMP banks, the same simple damping loops that have been inherited from the LASTI QUAD; a differentiator with a cutoff ([0:20,20]), and the 50Hz elliptical filter. Now that these filters are installed, as soon as the M1 BOSEMs are restored to the middle of the range, and properly diagonalized, we *should* be able to close damping loops (though it should be done cautiously at first!!).