Medms corrected re aLOG 12441

Through a series of unfortunate incidents, I ended up copying an older BSC-ISI Overview onto the current and lost changes made to naming of IOP_DACKILL channels.

However, following the guidence in the subject alog resulted in incorrect channel names.  The corrections to this guidence are:

 

$(IFO):IOP-SEI_$(IOP)_SEI$(CHAMBER)_DACKILL_STATE, with $(CHAMBER) taking the following values: 'BS', 'ITMX', 'ITMY', 'ETMX', 'ETMY'

This is not correct, it should be:

$(IFO):IOP-SEI_$(CHAMBER)_DACKILL_STATE, with $(CHAMBER) taking the following values: 'BS', 'ITMX', 'ITMY', 'ETMX', 'ETMY'

This line too in the medms needed to be corrected from $(IFO):IOP-$(IOP_NAME)_DACKILL_STATE  to $(IFO):IOP-SEI_$(CHAMBER)_DACKILL_STATE

I have added this correctioin to 12441.