The local sensors, both positional and inertial, are converted to Ligo Global Frame (assuming the ZL & ZG are collocated, which they are not, quite) via calibration filters and local to cartesian transformation matrices; this is done using the right hand rule, RHR. Many of the platforms for H1 were commissioned before much thought and diligence was put into these matrices. The seismic group has finalized these transforms and we can now correct the long standing errors. However, this will require taking platforms off line to load the matrices as well as new cartesian basis controllers and Position Targets for many of the platforms. We'll attempt to do this systematically during maintenance days and other opportunities.
Meanwhile, as I just finished an update to the state of these matrices, I thought a tabulation of the platforms was in order.
| HEPI | Impact | ISI | Impact | |
|
HAM1 |
Wrong | Magnitudes are correct so displacements are right but the rotational dofs have the wrong sign wrt RHR. | NA | iLIGO Platform |
| HAM2 | Wrong | Ditto | Wrong | Rotational dof signs are wrong for RHR |
| HAM3 | Wrong | Ditto | Wrong | Ditto |
| HAM4 | Correct | Signs & Amplitudes are right for examining platform movement | Wrong | CPS & GS13 matrices are good, correcting L4C2CART will not impact platform or alignment |
| HAM5 | Correct | Ditto | Wrong | Ditto |
| HAM6 | Correct | Ditto | Wrong | Ditto |
| ITMY | Wrong | X & Y dof mags wrong. ~x2 | Wrong | All good sans HEPI L4C Sencorr--no impact on use of sensors. |
| BS | Wrong | Rotation dof mags are incorrect, RZ x4, RX & RY x2 | Wrong | X Y RX & RY signs are wrong putting positional study in jeopardy |
| ITMX | Correct | Signs & Amplitudes are right for examining platform movement | Wrong | All good sans HEPI L4C Sencorr--no impact on use of sensors. |
|
ETMX
ETMY |
Correct
Correct |
Ditto
Ditto |
Wrong
Wrong |
X Y RX & RY signs are wrong putting positional study in jeopardy
Minor errors in off diag elements, basic study use okay but fixing will require completesweep through system. |