Reports until 09:24, Tuesday 14 October 2014
H1 ISC
edmond.merilh@LIGO.ORG - posted 09:24, Tuesday 14 October 2014 - last comment - 15:23, Thursday 16 October 2014(14437)
Removed failed ISC Whitening chassis from X-End

The ISC Whitening chassis S1101631 mentioned in Kiwamu's log entry (14430) was removed from the X-End LVEA electrnoics rack. The -15VDC failed. I also removed a small snake from the computer cart all snuggled up to the warm monitor and keyboard.

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 10:10, Tuesday 14 October 2014 (14438)

surprise I did not notice the snake!

edmond.merilh@LIGO.ORG - 15:23, Thursday 16 October 2014 (14487)

It was the +15 rail, not the -15. My bad.