sheila.dwyer@LIGO.ORG - posted 20:24, Friday 17 October 2014 - last comment - 10:18, Saturday 18 October 2014(14508)
DRMI is fine at 1 Watt, again.

Alexa, Sheila, Dan, Kiwamu

I was about to post the alog below, when we decided to go back to 1 Watt since everything else we have tried to get DRMI stable at 10 Watts has failed.  At 1 Watt we had no mode hopping issues, we aquire lock within 10 minutes or less, and it is stable once we lock.   This sounds like a familiar story.....

Right now we are trying to transition to 3F, we didn't suceed at 1 Watt so we are now trying at 2.9 Watts. 

The old, sad alog:

Today we tried to get PRMI to be stable again. Our working theory is that we are having these mode hopping problems beause of some bad alignment.  Our intial alingment scheme right now doesn't fix the alingment of PR3, so we have tried various methods to recover this alingment to a time when we had more stable locking.

We also got a DRMI lock, which lasted only a few minutes, and dropped at 1:53:07 october 18 UTC, that is the second video attached.   Our big victory today was that Alexa killed the fly that has been hanging out in the control room.

Non-image files attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 20:39, Friday 17 October 2014 (14510)

We tried increasing the input power to 4W; at this point DRMI was already unstable.

kiwamu.izumi@LIGO.ORG - 22:43, Friday 17 October 2014 (14511)

Alexa, Dan, Kiwamu

Tried several times of the 3f locking, but was not so successful because the SRCL loop did not like to be locked with the 3fs. Only once, we were able to transition to all the 3fs at 2.7 W. At this ponint the input element was 1, 2, 5 for PRCL, MICH and SRCL loops.

We started checking the demod phases. Surprisingly, it seems that the good demod phase for RF135 has changed from that of 10 W by more than 45 deg. MICH and SRCL show up mostly in the opposite quadrature. We should do more precise and careful adjustment for this

alexan.staley@LIGO.ORG - 10:18, Saturday 18 October 2014 (14512)

When we were at 2.7W and locked on 3f with MICH and PRCL, I measured the open loop transfer functions. The UGF and phase margin for PRCL has been the same as before (UGF of ~70Hz, with 40 deg phase margin). However, the UGF for MICH was too low, ~ 2.5 Hz.

Displaying report 1-1 of 1.