BRS output filter modified leading to better tilt-subtraction

J. Kissel, K. Venkateswara

The output filter for the BRS included two zeroes at 8.8 mHz and two poles at 1 mHz to compensate for the real pole of the beam-balance and a zero due to the gravitational spring (proportional to d, distance between CoM and pivot). Based on the data during windy periods (see 13563 and 14422), it looks like d is roughly -35 +/- 5 microns, which corresponds to an imaginary zero at ~7.3 mHz. Since Foton doesn't allow imaginary poles, I put in a complex pole with Q of 3 as an approximation but this means that the output is going to be incorrect between 5-10 mHz.

With this new output filter in place, the tilt-subtraction is working well above ~ 20 mHz. The attached pdf shows the ASD for the ground seismometer (blue), the tilt-subtracted super-sensor (red) and the tilt-correction output (green). Wind-speeds were in the range of 20-30 mph during this measurement. Note that while the super-sensor is lowered by a factor of ~5 at 50 mHz, the subtraction near 10 mHz is limited by the approximation I made above. If we could add the imaginary pole in Foton, the subtraction would be better.

Non-image files attached to this report
Comments related to this report
krishna.venkateswara@LIGO.ORG - 17:56, Monday 20 October 2014 (14527)

Another plot in displacement units and also showing Stage 1 motion. With sensor correction, the hope is to reduce the bump at 30-50 mHz by reducing tilt-reinjection and maintain performance at 0.5 Hz.

Non-image files attached to this comment