Displaying report 1-1 of 1.
Reports until 08:23, Tuesday 21 October 2014
H1 SEI
hugh.radkins@LIGO.ORG - posted 08:23, Tuesday 21 October 2014 (14535)
WBSC1 ITMY ISI Local2Cartesian & back are all correct. ISI-HEPI L4C Filters Good Safe.snap made

Copied all the Cal & Sym filters from the HEPI L4CINF banks to the ISI-HEPI L4CINF filters.  I did this with cut & paste in foton.  Corrected the ISI-HEPI L4C2CART matrix.  Safe.snap made.  ISI back under Guardian control.

The HEPI matrices are still in need of correcting but that will be more invasive.