Reports until 17:14, Tuesday 21 October 2014
H1 SUS (AOS)
jeffrey.kissel@LIGO.ORG - posted 17:14, Tuesday 21 October 2014 (14571)
H1SUSETMY Slider Calibration Refinement Installed
J. Kissel

Using the calibration calculated in LHO aLOG 14405, I've installed the new ETMY slider gains,
EY P =  19.341 [ct/urad]
   Y =  51.013 [ct/urad]
and saved adjusted alignment offsets for ALIGNED and MISALIGNED, confirming that the *output* of the OPTICALIGN bank is the same. After Jason centered the ETMY optical lever on the ALIGNED state (which had drifted way off, see LHO aLOG 14555), others needed the optic misaligned before I had the change to get measurements for refining the optical lever calibration. 

Will keep pecking away when time and commissioning permits, but still no refined optical lever calibration for the ETMs.