Reports until 12:27, Friday 24 October 2014
H1 AOS
krishna.venkateswara@LIGO.ORG - posted 12:27, Friday 24 October 2014 (14596)
BRS damper issues

R. Schofield, K. Venkateswara

The BRS damper was working incorrectly over the last few days. As described in 14388, the vibration from the damper occasionally drives up the beam-balance's fundamental mode. This lead to incosistent damping. On Wednesday night, Robert Schofield and I tried adding some foam under the turn-table platform, which seemed to help. The BRS damped down correctly that evening. The next day, it failed to damp again. I noticed that the foam had gotten squished almost completely, thus not providing much isolation.