Alexa, Evan
Daniel and Rana have pointed out that it doesn't make much sense to use AS_A_RF45 as a sensor for controlling the angular DOFs of sideband-locked PRMI/DRMI: the carrier is (intentionally) not resonant in these configurations, meaning that the 45 MHz RF signal is dominated by the 45 MHz sidebands beating against a weak (and potentially spatially junky) carrier signal. What we want instead is a signal which involves some sort of beating with the 9 MHz TEM00 mode, since this is resonant inside sideband-locked PRMI/DRMI. We propose to use AS_A_RF36 to feed back onto BS M2, since the 36 MHz signal involves the beating of the 9 MHz sidebands with the (co-resonant) 45 MHz sidebands. This is what is used at LLO (see Den's slides at G1400981).
We've done the following to prepare AS_A_RF36Q for use with the ASC loops:
To proceed from here, we need to: