Reports until 09:52, Friday 24 October 2014
H1 SEI (INS)
hugh.radkins@LIGO.ORG - posted 09:52, Friday 24 October 2014 (14606)
H1 SEI Transformation Matrices Status Update
  HEPI            Impact ISI Impact aLOG  

HAM1      

Wrong Magnitudes are correct so displacements are right but the rotational dofs have the wrong sign wrt RHR. NA             iLIGO Platform  
HAM2 Wrong Ditto Wrong Rotational dof signs are wrong for RHR  
HAM3 Wrong Ditto Wrong Ditto  
HAM4 Correct Signs & Amplitudes are right for examining platform movement Correct Signs & Amplitudes are right for examining platform movement 14383
HAM5 Correct Ditto Correct Signs & Amplitudes are right for examining platform movement 14480
HAM6 Correct Ditto Correct Signs & Amplitudes are right for examining platform movement 14516
ITMY Wrong X & Y dof mags wrong. ~x2 Correct Signs & Amplitudes are right for examining platform movement 14578
BS Wrong Rotation dof mags are incorrect, RZ x4, RX & RY x2 Wrong X Y RX & RY signs are wrong putting positional study in jeopardy  
ITMX Correct Signs & Amplitudes are right for examining platform movement Correct Signs & Amplitudes are right for examining platform movement 14535
ETMX
ETMY
Correct
Correct
Ditto
Ditto
Wrong
Wrong
X Y RX & RY signs are wrong putting positional study in jeopardy
Minor errors in off diag elements, basic study use okay but fixing will require completesweep through system.
 

Above is an update to my 14373 SEI Matrices Status.  The Blue Entries are new status since the 8 Oct report.  Greens are all good and the reds are Platforms still requiring attention.