Reports until 10:25, Friday 24 October 2014
H1 SEI
hugh.radkins@LIGO.ORG - posted 10:25, Friday 24 October 2014 (14608)
HAM2 Performance Spectra post yesterday's fun with 01_28 blends and 100mHz blends X Y Z

re 14594, the WHAM2 ISI config change attempt yesterday.  Attached are performance spectra from this moring at 3am, and at 8am this morning after I switched the ISI back to the same configuration before we started--that is with the X Y Z blends switched from 01-28 to 100mHz.

I'd say the differences are minor and no great improvement but the ground noise is also slightly higher at 8am.  Plus it would be a lot easier with overlay plots.

I'm pretty sure we've decide to actually run with all the HAM ISI dofs to be the 01_28 blends.  THe X Y Z dofs being in 100mz is a left over from when Sebastien was working on Sensor Correction.

Images attached to this report