PSL ISS diffracted power adjustment

PSL ISS REFSIGNAL adjusted to -2.09V, bringing the Diffracted Power ~7.5%.

Comments related to this report
travis.sadecki@LIGO.ORG - 13:05, Monday 27 October 2014 (14642)

This adjustment caused the ISS loop to drop lock.  The autolocker brought it back up each time.  After seeing this happen several times, I readjusted the REFSIGNAL to -2.08V, bringing the diffracted power to ~9%.  It has now been stable for ~1.5 hours.  I'll continue to montior this during my shift.