QUAD Model Updates Complete (WP#4915)
[Jeff K, Stuart A]

Following work yesterday preparing QUAD model updates (see LHO aLOG entry 14645), we convened early this morning to rebuild, install and restart models. 

A detailed log of our activities follows:-

- Bring down the IMC to DOWN state via Guardian (no change to LSC model)
- Bring down QUADs to SAFE state via Guardian
- Bring down SEI to OFFLINE state via Guardian  
- Capture new safe BURT snapshots for h1lsc, h1susetmx, h1susetmy, h1susitmx and h1susitmx
- Made all QUADs
- Installed all QUADs
- Restarted all QUADs
- Svn-up updated QUAD MEDM screens
- Untripped all Watchdogs
- Restore QUAD alignments
- Restore SEIs to FULLY_ISOLATED via Guardian 
- Restore IMC to LOCKED via Guardian
- DAQ process restart at 14:29 (UTC)
- Update other SUS MEDM screens (see LLO aLOG entry 15004) 
- Cleaned errant IPC issues with diag reset on GDS TP screen
- Committed new safe BURT snapshots to svn

Summary of benefits:

This now makes damping of violin, bounce and roll modes possible via the the L2 (PUM) stage of all QUADs using DARM error. Other benefits include: ESD linearization, providing infrastructure for remote ESD activation and deactivation. Also, old Guardian infrastructure has been removed from the model and MEDM screen, with new Guardian embedded mini control-panel replacing them in the QUAD Overview MEDM screen (as well as for other Suspensions too)

This closes-out WP#4915.
Images attached to this report
Comments related to this report
stuart.aston@LIGO.ORG - 08:14, Tuesday 28 October 2014 (14659)
We also updated the h1susauxex and h1susauxey models to provide analog and digital monitoring of the ESD Driver, as has been carried out at LLO (see LLO aLOG entry 12688).
Images attached to this comment
stuart.aston@LIGO.ORG - 09:17, Thursday 30 October 2014 (14726)
The updated local top level SUS QUAD and SUS AUX models have been committed to the svn:-

/opt/rtcds/userapps/release/sus/h1/models/
M        h1susetmx.mdl
M        h1susetmy.mdl
M        h1susitmx.mdl
M        h1susitmy.mdl
M        h1susauxex.mdl
M        h1susauxey.mdl