Reports until 10:44, Tuesday 28 October 2014
H1 SYS
jameson.rollins@LIGO.ORG - posted 10:44, Tuesday 28 October 2014 - last comment - 19:33, Tuesday 28 October 2014(14660)
guardian/cdsutils upgrades

I upgraded the guardian core and cdsutils (python ezca) installs:

I restarted most of the nodes, except for the following:

jameson.rollins@opsws2:~/src/cdsutils/trunk 0$ guardctrl list | grep -v 1095
node         s k m vers  state                                    message
----         - - - ----  -----                                    -------
ALS_COMM     o - -    -  -                                        -
H1ECATC1PLC2 *   E 1076  INIT                                     
H1ECATX1PLC2 *   E 1076  INIT                                     
H1ECATY1PLC2 *   E 1076  INIT                                     
H1ISCEX      *   E 1076  INIT                                     
H1ISCEY      *   E 1076  INIT                                     
H1LSC        *   E 1076  INIT                                     
H1LSCAUX     *   E 1076  INIT                                     
HPI_HAM2     * * M 1083  ROBUST_ISOLATED                          
IAS_INPUT    o - -    -  -                                        -
IAS_MICH     o - -    -  -                                        -
IAS_PRC      o - -    -  -                                        -
IAS_SRC      o - -    -  -                                        -
IAS_TEST     o - -    -  -                                        -
IAS_XARM     o - -    -  -                                        -
IAS_YARM     o - -    -  -                                        -
IFO_ALIGN    o - -    -  -                                        -
ISC_LOCK     o - -    -  -                                        -                            
ISI_HAM2     *   P 1083  WATCHDOG_TRIPPED_FULL_SHUTDOWN           WATCHDOG TRIP: FULL_SHUTDOWN (4)                       
LSC          *   E 1076  INIT                                     
LSC_PRMI_VAR_FINESSE *   E 1083  DOWN                                     MISALIGN PRM
LSC_PRX      *   P 1083  FAULT                                    check LSC input matrix, ITMY not MISALIGNED
LSC_PRY      *   P 1080  FAULT                                    PRM not ALIGNED, ITMX not MISALIGNED
SEI_HAM2     *   P 1083  ISOLATED                                   
SUS_MC1      * * E 1080  ALIGNED                                  
SUS_MC3      * * E 1080  ALIGNED                                  
SUS_PR3      * * E 1080  ALIGNED                                  
SUS_PRM      * * M 1083  ALIGNED  

The non-running nodes (s='o') had various errors on restart, so I shut them down until they can be fixed.  I shut down all the IAS nodes since I was told they're not in use.  The HAM2 nodes were not restarted because Hugh was in the middle of doing some SEI work on HAM2.  The nodes starting with "H1" are the "CSDEF" nodes (not sure what the status of those is).  I'll restart these nodes when I'm sure it's ok.

I noticed that there are a couple of "hidden" nodes, that are not listed in the Guardian overview screen:

H1ECATC1PLC2 *   E 1076  INIT                                     
H1ECATX1PLC2 *   E 1076  INIT                                     
H1ECATY1PLC2 *   E 1076  INIT                                     
H1ISCEX      *   E 1076  INIT                                     
H1ISCEY      *   E 1076  INIT                                     
H1LSC        *   E 1076  INIT                                     
H1LSCAUX     *   E 1076  INIT   LSC          *   E 1076  INIT                                     
LSC_PRMI_VAR_FINESSE *   E 1083  DOWN                                     MISALIGN PRM
LSC_PRX      *   P 1083  FAULT                                    check LSC input matrix, ITMY not MISALIGNED
LSC_PRY      *   P 1080  FAULT                                    PRM not ALIGNED, ITMX not MISALIGNED

We should be very careful about these.  If they're being used, they should be on the overview.  If they're not being used, they should be shut down.  Do not leave running nodes off of the overview screen

Comments related to this report
jameson.rollins@LIGO.ORG - 10:47, Tuesday 28 October 2014 (14668)

I should note that a bug was fixed in the cdsutils avg function.  The standard deviation calculations were bogus, off by some unknown but large factor.  This new version fixes that issue so that the standard deviation calculations returned with the "stdev" option are now correct.

jameson.rollins@LIGO.ORG - 10:54, Tuesday 28 October 2014 (14669)
sheila.dwyer@LIGO.ORG - 19:33, Tuesday 28 October 2014 (14692)

We have reverted the cdsutils to cdsutils-329 (the version installed here since september), we did this by changing the link in /ligo/apps/linux-x86_64

The guardians were failing when they called the new avg function, we tried using the new cds utils function from the command line but it doesn't seem to be working.