Reports until 10:45, Thursday 30 October 2014
H1 SUS
stuart.aston@LIGO.ORG - posted 10:45, Thursday 30 October 2014 (14733)
Corrected QUAD Overview MEDM DARM Error Damping Displays
I noticed that the DARM Error damping display on the QUAD MEDM Overview screen was showing the incorrect channel information. So I substituted them for the correct channels (H1:SUS-ITMY_L2_DAMP_MODE1_OUTPUT, H1:SUS-ITMY_L2_DAMP_MODE2_OUTPUT etc.) and committed the fixed screen to the userapps svn, as follows:-

/opt/rtcds/userapps/release/sus/common/medm/quad/
M        SUS_CUST_QUAD_OVERVIEW.adl

This will need to be svn'd up at LLO too.