Required central heating to correct ITMX static lens: 201mW

Based on the TCSX central heating calibration (62.3 micro-diopters single-pass per Watt) and the calculated static lens of -80213m, we require:

+201mW of central heating on ITMX to correct this static lens.

Edited 31-Oct-2014: this isn't correct because of an error in the laser power calibration

Comments related to this report
aidan.brooks@LIGO.ORG - 11:10, Friday 31 October 2014 (14773)

The calibration of defocus vs delivered power is incorrect as the delivered power channel, H1:TCS-ITMX_CO2_LSRPWR_MTR_OUTPUT, was not calibrated correctly.

I went back and reviewed the delivered power for this measurement:

Before thermal lens: H1:TCS-ITMX_CO2_LSRPWR_MTR_INMON = 172.7 counts

During thermal lens H1:TCS-ITMX_CO2_LSRPWR_MTR_INMON = 2113.4 counts

The new gain through the filter banks is 7.2087E-4 Watts per count.

This means 1.399 Watts was applied to ITMX during the thermal lens measurement.

Further analysis of the HWS measurements of the thermal lens show:

  • the (double-passed) change in spherical power was 78.7 micro-diopters after 4.5 hours (close to steady-state).
  • the applied power was 1.399 mW

Therefore, the single-passed ITMX steady-state thermal lens coefficient is 28.1 micro-diopters per Watt

Based on the TCSX central heating calibration and the calculated static lens of -80213m, we require:

+444mW of central heating on ITMX to correct this static lens.