jeffrey.kissel@LIGO.ORG - posted 15:35, Wednesday 28 September 2011 (1477)
Created h2sustmsy.mdl
I've finished creating a simulink control model for the H2 SUS TMSY. It lives under
${RTCDSROOT}/userapps/release/sus/h2/models/h2sustmsy.mdl

I've followed the latest versions of 
T1000588-v6 -- to get the DCUID (99), front end computer (h2susetmy), and specific_cpu (3 -- remember core counting in Rolf's document starts at 1, where as it starts from 0 in the model)
D1002741-v2 -- to get the ADC, DAC, and BIO mapping.
and used the recently developed library parts
${RTCDSROOT}/userapps/release/sus/common/models/
SIXOSEM_F_COILOUTF_MASTER.mdl
SIXOSEM_F_STAGE_MASTER.mdl
SIXOSEM_F_WD_AC_MASTER.mdl
SIXOSEM_F_WD_DC_MASTER.mdl
to create
${RTCDSROOT}/userapps/release/sus/common/models/TMTS_MASTER.mdl

I've successfully compiled it on h2build and I've also make-installed it. Since h2susetmy (the front end) isn't hooked up to the network yet, I haven't tried starting it.

Working on generic overview screens meow. Should get them out by tomorrow.