david.barker@LIGO.ORG - posted 14:06, Friday 31 October 2014 (14776)
SUS-DRIFTMON: h1susauxh34 modified, DAQ restarted

Dave, Jeff [WP 4927]

the h1susauxh34 model  was modified to add EPICS channels to support the SUS Drift Mon program. The model was restarted at 13:22 and the DAQ was restarted to resync at 13:32. It was not a clean DAQ restart, mx-streams had to be restarted on h1pemmx, h1pemmy, h1susex and h1susauxex.

I reverted out my local changes to the driftmon files (changes needed when we didn't have the supporting epics channels) and svn updated this code to the latest version.

The Driftmon MEDM is linked to the SITEMAP via the SUS button on the left-hand block (see attached)

The python script to update the alarm levels is in the general search path. To run it to update all suspension the command is

driftmon_update.py H1 -H nds2.ligo-wa.caltech.edu -P 31200 -l 3600 -d 600 --minor-stdev=4 --major-stdev=5 --all

This gets data starrting one hour ten minutes ago up to one hour ago.

This closes out WP 4927.