Top level differences between H1 and L1 for interferometer locking

The difficulties with H1 DRMI locking, and with getting H1 to full lock, prompt me to survey the top level configuration differences between H1 and L1.

Some other comparisons that should be made (not in the table) are:

At this point we don't know which of these differences, if any, are significant for the lock acquision. Please post comments to this entry if you have some ideas on this, or if there are other known differences that we should be looking at.

parameter L1 H1 comments
 input power for locking 2 W 10 W

 

 modulation depths, 9/45 MHz 0.25/0.29 0.19/0.28

not sure if L1 values are current

 ETM global feedback hierarchical distributed

 

 SUS local damping A B

They're different; see G1401267; Jeff K and Stuart A are working on comparison plots

 DRMI ASC servos 4 loops 3 loops

BW probably lower on H1; more complete comparison needed

 HSTS feedback & coil drivers increased M2 drive for PRM & SRM increased M2 & M3 drive for all HSTS  
 LSC servo loops    

comparison needs to be made

 3-f PD photocurrent (DRMI) 0.15 ma 27 mW -> 3 ma

H1 has done limited trials with a reduced photocurrent

 WFS centering loops    

different, but comparison needed

 ALS ETM feedback ? Done when needed to bring frequency in range  
 Michelson contrast defect: modeled, no arms, no TCS 6400 ppm 10,800 ppm

SIS model, using as-built ITMs

 Modeled power recycling gain: carrier, no arms, no TCS 40 33

SIS model, using as-built ITMs

Comments related to this report
peter.fritschel@LIGO.ORG - 13:44, Tuesday 04 November 2014 (14839)

RF spectra from the 3-f BBPD have been posted to both LHO and LLO logs recently, so here is a comparison of those.

LLO data: log 15430  , photocurrent: 0.21 ma

LHO data: log 14807 , 27 mW -> inferred photocurrent: 3.0 ma (better would be a direct measurement of photocurrent)

Comparison of 6 highest RF peaks:

Frequency L1 H1 Delta
9 MHz -41 dBm -11 dBm +30
18 MHz -29 dBm -12 dBm +17
36 MHz -18 dBm -1 dBm +17
45 MHz -30 dBm -12 dBm +18
54MHz -25 dBm -6 dBm +19
90 MHz -33 dBm -14 dBm +19

 

 

 

 

 

 

 

 

Other than 9 MHz, the BBPD output RF components on H1 are all about 20 dB higher than the corresponding components for L1. This is about what is expected from the higher photocurrent used on H1 -- in fact we'd expect closer to 24 dB, if the inferred H1 photocurrent is right. The 9 MHz on H1 is another 10 dB higher (on top of the 20 dB), which is odd considering that the f1 modulation depth on H1 is smaller. This may indicate that on 3-f locking, there is more of an offset on PRCL (or MICH?) in H1 than L1, or maybe more residual motion.