SUS ODC updates today
With approval from Jeff K, I am about to begin updating the EPICS settings controlling the ODC (state vector) for the SUS subsystem.
These changes include:

- Update bit strings to latest configuration, including OPLEV damping names
- Update bitmasks to not include LOCK state checks in ODC summary bits
- Update and commit safe.snap files to capture the above changes

These changes will not affect any EPICS settings not under the 'H1:SUS-{optic}_ODC' prefix.
Comments related to this report
duncan.macleod@LIGO.ORG - 08:18, Tuesday 04 November 2014 (14823)
This work is now complete. Please see r9059 for details of the safe.snap file changes.

The ODC settings for the SUS subsystem should now be the same across both LIGO sites.